Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Agric Food Chem ; 71(42): 15732-15744, 2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37820072

RESUMO

The oxidation reactions that take place in virgin olive oil under moderate conditions involved the combined effect of antioxidant and prooxidant compounds. Given the complexity of oxidation processes of multicomponent matrices, there is still a need to develop new methods with a dynamic approach to study the persistence of the compounds with healthy properties. This work studied the joint evolution of them, including phenols and pheophytin a, modeling their tendency during a real storage. The regression equations performed with the total phenol concentration showed that around 2% of the concentration was lost every month. Simultaneously, the progress of oxidation was evaluated by mesh cell incubation and Fourier transform infrared analysis. This method pointed out that, in the presence of light, the prooxidant effect of pigments was able to mask the protective effect of phenols, until the pheophytin a concentration was lower than 1 mg/kg. The antioxidant effect of phenols was less remarkable when the concentration loss was 35% or more.


Assuntos
Fenóis , Telas Cirúrgicas , Azeite de Oliva/análise , Fenóis/análise , Antioxidantes , Oxirredução , Óleos de Plantas
2.
Foods ; 9(10)2020 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-33096623

RESUMO

The commercial category of virgin olive oil is currently assigned on the basis of chemical-physical and sensory parameters following official methods. Considering the limited number of samples that can be analysed daily by a sensory panel, an instrumental screening tool could be supportive by reducing the assessors' workload and improving their performance. The present work aims to in-house validate a screening strategy consisting of two sequential binary partial least squares-discriminant analysis (PLS-DA) models that was suggested to be successful in a proof-of-concept study. This approach is based on the volatile fraction fingerprint obtained by HS-SPME-GC-MS from more than 300 virgin olive oils from two crop seasons graded by six different sensory panels into extra virgin, virgin or lampante categories. Uncertainty ranges were set for the binary classification models according to sensitivity and specificity by means of receiver operating characteristics (ROC) curves, aiming to identify boundary samples. Thereby, performing the screening approach, only the virgin olive oils classified as uncertain (23.3%) would be assessed by a sensory panel, while the rest would be directly classified into a given commercial category (78.9% of correct classification). The sensory panel's workload would be reduced to less than one-third of the samples. A highly reliable classification of samples would be achieved (84.0%) by combining the proposed screening tool with the reference method (panel test) for the assessment of uncertain samples.

3.
Foods ; 9(7)2020 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-32630810

RESUMO

This research aims to develop a classification model based on untargeted elaboration of volatile fraction fingerprints of virgin olive oils (n = 331) analyzed by flash gas chromatography to predict the commercial category of samples (extra virgin olive oil, EVOO; virgin olive oil, VOO; lampante olive oil, LOO). The raw data related to volatile profiles were considered as independent variables, while the quality grades provided by sensory assessment were defined as a reference parameter. This data matrix was elaborated using the linear technique partial least squares-discriminant analysis (PLS-DA), applying, in sequence, two sequential classification models with two categories (EVOO vs. no-EVOO followed by VOO vs. LOO and LOO vs. no-LOO followed by VOO vs. EVOO). The results from this large set of samples provide satisfactory percentages of correctly classified samples, ranging from 72% to 85%, in external validation. This confirms the reliability of this approach in rapid screening of quality grades and that it represents a valid solution for supporting sensory panels, increasing the efficiency of the controls, and also applicable to the industrial sector.

4.
Foods ; 9(3)2020 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-32204346

RESUMO

A set of 334 commercial virgin olive oil (VOO) samples were evaluated by six sensory panels during the H2020 OLEUM project. Sensory data were elaborated with two main objectives: (i) to classify and characterize samples in order to use them for possible correlations with physical-chemical data and (ii) to monitor and improve the performance of panels. After revision of the IOC guidelines in 2018, this work represents the first published attempt to verify some of the recommended quality control tools to increase harmonization among panels. Specifically, a new "decision tree" scheme was developed, and some IOC quality control procedures were applied. The adoption of these tools allowed for reliable classification of 289 of 334 VOOs; for the remaining 45, misalignments between panels of first (on the category, 21 cases) or second type (on the main perceived defect, 24 cases) occurred. In these cases, a "formative reassessment" was necessary. At the end, 329 of 334 VOOs (98.5%) were classified, thus confirming the effectiveness of this approach to achieve a better proficiency. The panels showed good performance, but the need to adopt new reference materials that are stable and reproducible to improve the panel's skills and agreement also emerged.

5.
Molecules ; 24(13)2019 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-31269664

RESUMO

Τoward a harmonized and standardized procedure for the determination of total hydroxytyrosol and tyrosol content in virgin olive oil (VOO), the pros of a recently published in house validated ultra high performance liquid chromatography (UHPLC) protocol are discussed comparatively with those of other procedures that determine directly or indirectly the compounds hosted under the health claim on "olive oil polyphenols" (EC regulation 432/2012). Authentic VOOs were analyzed with five different liquid chromatographic separation protocols and 1H-NMR one in five different laboratories with expertise in VOO phenol analysis within three months. Data comparison indicated differences in absolute values. Method comparison using appropriate tools (Passing-Bablok regression and Bland Altman analyses) for all protocols vs. the UHPLC one indicated slight or statistically significant differences. The results were also discussed in terms of cost effectiveness, detection means, standard requirements and ways to calculate the total hydroxytyrosol and tyrosol content. Findings point out that the in-house validated fit for the purpose UHPLC protocol presents certain pros that should be exploited by the interested parties. These are the simplicity of sample preparation, fast elution time that increase the number of samples analyzed per day and integration of well-resolved peaks with the aid of only two commercially available external standards. Importance of correction factors in the calculations is stressed.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Azeite de Oliva/química , Álcool Feniletílico/análogos & derivados , Álcool Feniletílico/análise , Espectroscopia de Prótons por Ressonância Magnética , Padrões de Referência
6.
Food Chem ; 295: 94-100, 2019 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-31174814

RESUMO

The present work aimed at examining the combined effect of chlorophyll content and light filtering packaging material on the photo-stability of virgin olive oil (VOO) via mesh cell-FTIR spectroscopy monitoring. Four different VOOs of Koroneiki cultivar differing in total chlorophyll content (∼12-46 mg/kg) were exposed in parallel to direct visible light (6000 lx, 24 °C, 344 h) and FTIR spectra were recorded periodically with or without applying light protection by an industrial filter used for packaging. Findings suggested that the protective role of light filtering material was more evident in the VOO with the lowest total chlorophyll content. Real time monitoring of VOO by mesh cell-FTIR was found to be a useful tool to follow the combined effect of pro-oxidant chlorophylls and the protective light filtering materials on the photo-oxidation process of VOO employing a minute sample amount.


Assuntos
Clorofila/química , Embalagem de Alimentos/métodos , Azeite de Oliva/química , Espectroscopia de Infravermelho com Transformada de Fourier , Ácidos Graxos/química , Luz , Oxirredução
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...